RESOLUTION MEPC.355(78)
(adopted on 10 June 2022)
2022 INTERIM GUIDELINES ON CORRECTION FACTORS AND VOYAGE
ADJUSTMENTS FOR CII CALCULATIONS (CII GUIDELINES, G5)
THE MARINE ENVIRONMENT PROTECTION COMMITTEE,
RECALLING Article 38(a) of the Convention on the International
Maritime Organization concerning the functions of the Marine Environment
Protection Committee (the Committee) conferred upon it by international
conventions for the prevention and control of marine pollution from ships,
NOTING that the Committee, at its seventy-sixth session, adopted,
by resolution MEPC.328(76),
the 2021 Revised MARPOL Annex VI, which will enter into force on 1
November 2022,
NOTING IN PARTICULAR that the 2021 Revised MARPOL Annex VI
(MARPOL Annex VI) contains amendments concerning mandatory goal-based technical
and operational measures to reduce carbon intensity of international shipping,
NOTING ALSO that regulation 28.1 of MARPOL Annex VI requires ships
to which this regulation apply to calculate the attained annual operational
carbon intensity indicator (CII) taking into account the guidelines developed
by the Organization,
NOTING FURTHER that the in adopting resolution MEPC.336(76) on
the 2021 Guidelines on operational carbon intensity indicators and the
calculation methods (CII Guidelines, G1), the Committee agreed to
consider substantiated proposals for CII correction factors for certain ship
types, operational profiles and/or voyages with a view to enhancing, as
appropriate, the CII Guidelines (G1), before entry into force of the
aforementioned amendments to MARPOL Annex VI,
RECOGNIZING that the aforementioned amendments to MARPOL Annex VI
require relevant guidelines for uniform and effective implementation of the
regulations and to provide sufficient lead time for industry to prepare,
HAVING CONSIDERED, at its seventy-eighth session, the draft 2022
Interim Guidelines on correction factors and voyage adjustments for CII
calculations (CII Guidelines, G5),
1 ADOPTS the 2022
Interim Guidelines on correction factors and voyage adjustments for CII
calculations (CII Guidelines, G5), as set out in the annex to the present
resolution;
2 INVITES
Administrations to take the annexed Guidelines into account when developing and
enacting national laws which give force to and implement requirements set forth
in regulation 28.1 of MARPOL Annex VI;
3 REQUESTS the
Parties to MARPOL Annex VI and other Member Governments to bring the annexed
Guidelines to the attention of masters, seafarers, shipowners, ship operators
and any other interested parties;
4 AGREES to keep the
Guidelines under review in light of experience gained with their
implementation, also taking into consideration that in accordance with
regulation 28.11 of MARPOL Annex VI a review of the operational measure to
reduce carbon intensity of international shipping shall be completed by 1
January 2026.
ANNEX
2022 INTERIM GUIDELINES ON CORRECTION FACTORS AND VOYAGE
ADJUSTMENTS FOR CII CALCULATIONS (CII GUIDELINES, G5)
CONTENTS
1 INTRODUCTION
2 DEFINITIONS
3 APPLICATION
4 ATTAINED ANNUAL
OPERATIONAL CII (CIISHIP) FORMULA FOR VOYAGE ADJUSTMENTS AND
CORRECTION FACTORS
APPENDIX 1 - CORRECTION FACTORS FOR USE IN CII CALCULATION
APPENDIX 2 - GUIDANCE ON REPORTING OF FUEL OIL CONSUMPTION AND
DISTANCE TRAVELLED FOR VOYAGE PERIODS WHERE THE SHIP MEETS THE CRITERIA TO
APPLY ANY VOYAGE ADUSTMENT
1 Introduction
1.1 These Guidelines
address the corrections factors and voyage adjustments which may be applied to
the calculation of the attained annual operational carbon intensity indicator
(CIIship) of regulation 28 of MARPOL Annex VI, and as defined by the
2022 Guidelines on operational carbon intensity indicators and the
calculation methods (CII Guidelines, G1) (resolution MEPC.352 (78)).
It should be noted that the use of correction factors and voyage adjustments
should in no way undermine the goal of reducing the carbon intensity of
international shipping as set out in regulation 20 of MARPOL Annex VI.
2 Definitions
For the purpose of these Guidelines, the definitions in regulation
2 of MARPOL Annex VI, as amended, apply. In addition and for the scope of these
guidelines, the following definitions apply.
2.1 MARPOL means
the International Convention for the Prevention of Pollution from Ships, 1973,
as modified by the Protocols of 1978 and 1997 relating thereto, as amended.
2.2 IMO DCS
means the IMO Ship Fuel Oil Consumption Database referred to in regulation 27
and related provisions of MARPOL Annex VI.
2.3 A voyage period
is a period of time where the ship meets the criteria to apply a voyage
adjustment in these Guidelines.
2.4 A voyage
adjustment deducts relevant fuel consumption, as well as the associated
distance travelled from the calculation of attained CII for a defined period
subject to certain threshold conditions being met.
2.5 A correction
factor means a factor in the numerator or denominator of the CII formula
which adjusts the calculation of the attained CII.
2.6 A refrigerated
container is an intermodal shipping container that is refrigerated
(including chilled and frozen containers) or heated for the transportation of
temperature-sensitive cargo, which will receive its power from the ship's power
supply.
2.7 Ice edge is
defined by paragraph 4.4. of the WMO Sea-Ice Nomenclature, March 2014 as the
demarcation at any given time between the open sea and sea ice of any kind,
whether fast or drifting.
2.8 A tanker should be
considered in Ship-to-Ship (STS) operation when operating in accordance
with regulation 41.2 of MARPOL Annex I and applying the best practices in
accordance with the OCIMF Ship to Ship Transfer Guide for Petroleum, Chemical
and Liquefied Gases. For the purpose of these guidelines, a tanker is engaged
in an STS voyage if a voyage between cargo loading and cargo discharging
locations, or a voyage between cargo discharging and cargo loading locations
does not exceed 600 nautical miles and the time for each of these voyages
(which does not include port or discharge time) is limited to 72 hours.
2.9 A shuttle tanker
is a tanker which is equipped with dynamic positioning and specialized cargo
handling equipment making it capable of loading crude oil at offshore
installations.
2.10 A self-unloading
bulk carrier is a bulk carrier with an onboard cargo handling system that
is utilized to discharge dry bulk cargo via a boom conveyor or shipboard cargo
pipeline equipment.
3 Application
3.1 For all ships to
which regulation 28 of MARPOL Annex VI applies, the operational carbon
intensity formula defined in section 4 should be applied when using voyage
adjustments or correction factors.
3.2 Rating of ships
according to the 2022 Guidelines on the operational carbon intensity rating
of ships (CII Rating Guidelines G4) (resolution MEPC.354(78)) should be carried out using the
corrected attained annual operational CII.
3.3 Corrections factors
for electrical related fuel consumption 𝐹𝐶𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑎𝑙,
boiler consumption 𝐹𝐶𝑏𝑜𝑖𝑙𝑒𝑟,
and other related fuel consumption 𝐹𝐶𝑜𝑡ℎ𝑒𝑟𝑠
should not be used for periods where voyage adjustments apply.
4 Attained annual
operational CII (CIIShip) formula for voyage adjustments and
correction factors
Use of voyage adjustments and correction factors require changes
to be made to the overall attained annual operational CII (CIIShip)
formula as follows:

Where:
• CFj represents the fuel mass
to CO2 mass conversion factor for fuel type j, in line with
those specified in the 2018 Guidelines on the method of calculation of the
attained EEDI for new ships (resolution MEPC.308(73) as amended by resolutions MEPC.322(74) and
MEPC.332(76)),
as may be further amended);
• FCj is the total mass of
consumed fuel of type j in the calendar year, as reported under IMO DCS,
converted to grams;
• FCvoyage,j is the mass (in
grams) of fuel of type j, consumed in voyage periods during the calendar
year which may be deducted according to paragraph 4.1 of these Guidelines;
• TFj = (1 − AFTancer)
· FCs,j represents the quantity of fuel j removed
for STS or shuttle tanker operation, where FCs,j = FCj
for shuttle tankers and FCs,j is the total quantity of fuel j
used on STS voyages for STS ships. If TFj > 0 then FCelectrical,j
= FCboiler,j = FCothers,j = 0;
• AFTancer represents the
correction factor to be applied to shuttle tankers or STS voyages according to
paragraph 4.2 of these Guidelines;
• yi s a consecutive numbering
system starting at y2023 = 0, y2024 = 1, y2025
= 2, etc;
• FCelectrical,j is the mass
(in grams) of fuel type j, consumed for production of electrical power
which is allowed to be deducted according to paragraph 4.3 of these Guidelines;
• FCboiler,j is the mass (in
grams) of fuel type j, consumed by the boiler which may be deducted
according to paragraph 4.4 of these Guidelines;
• FCothers,j is the mass (in
grams) of fuel type j, consumed by other related fuel consumption
devices according to paragraph 4.5 of these Guidelines;
• fi is the capacity
correction factor for ice-classed ships as specified in the 2018 Guidelines
on the method of calculation of the attained EEDI for new ships (resolution
MEPC.308(73) as amended by resolutions MEPC.322(74) and MEPC.332(76), as may be
further amended);
• fm is the factor for
ice-classed ships having IA Super and IA as specified in the 2018 Guidelines
on the method of calculation of the attained EEDI for new ships (resolution
MEPC.308(73) as amended by resolutions MEPC.322(74) and MEPC.332(76), as may be
further amended);
• fc represents the cubic
capacity correction factors for chemical tankers as specified in paragraph
2.2.12 of the 2018 Guidelines on the method of calculation of the attained
EEDI for new ships (resolution MEPC.308(73) as amended by resolutions MEPC.322(74)
and MEPC.332(76), as may be further amended);
• fj,VSE represents the
correction factor for ship-specific voluntary structural enhancement as
specified in paragraph 2.2.11.2 of the 2018 Guidelines on the method of
calculation of the attained EEDI for new ships (resolution MEPC.308(73) as
amended by resolutions MEPC.322(74) and MEPC.332(76), as may be further
amended), to be applied only to self-unloading bulk carriers;
• Capacity is deadweight or gross tonnes
as defined for each specific ship type in the 2022 Guidelines on the
reference lines for use with operational carbon intensity indicators (CII
Reference lines Guidelines, G2) (resolution MEPC.353(78));
• Dt represents the total
distance travelled (in nautical miles), as reported under IMO DCS; and
• Dx represents distance
travelled (in nautical miles) for voyage periods which may be deducted from CII
calculation according to paragraph 4.1 of these Guidelines.
In case the above voyage exclusion or correction factors are
applied, the ship should still report total fuel oil consumption (t) of each
type of fuel, total hours under way (h) and total distance travelled (nm) to
the Administration pursuant to regulation 27 of MARPOL Annex VI.
All relevant data should be recorded in the ship's logbook. Each
parameter, if used, should also be reported to the Administration.
4.1 FCvoyage, j
for voyage adjustment
The parameter FCvoyage, j is the total mass (in
grams) of fuel of type 𝑗,
consumed in voyage periods during the calendar year which may be deducted from
the calculation of the attained CII in case the ship encounters one of the
following situations:
.1 scenarios specified in regulation 3.1 of
MARPOL Annex VI, which may endanger safe navigation of a ship; and
.2 sailing in ice conditions, which means
sailing of an ice-classed ship in a sea area within the ice edge.
In cases where FCvoyage, j is used:
• any associated distance travelled must also be
deducted using Dx otherwise ships will benefit from distance
travelled without any associated CO2 emission.
• the ship should report data for the deductions
associated with voyage adjustments to the Administration in accordance with
appendix 2 of these guidelines.
4.2 AFTanker,
for corrections to shuttle tankers or STS voyages on tankers
Tankers engaged in STS voyages as defined above in paragraph 2.8
may apply the correction factor AFTanker,STS to all fuel
consumption relating to STS voyages, including cargo transfer at offshore
location, voyage, cargo discharge and waiting periods at anchor or drifting
during which the ship reports being part of an STS operation and voyage. The
STS operation includes fuel consumption in port where the transferred cargo is
discharged after such a voyage.
The correction is calculated as:
AFTanker,STS = 6.1742 · DWT −0.246
Where AFTanker,STS is applied, FCelectrical,
FCboiler and FCothers should not be used.
Shuttle tankers equipped with dynamic positioning as defined above
in paragraph 2.9 may apply the correction factor AFTanker,Shuttle
to total fuel consumption:
The correction factor is calculated as:
AFTanker,Shuttle = 5.6805 · DWT −0.208
Where AFTanker,Shuttle is applied, FCelectrical,
FCboiler, FCothers and AFTanker,STS
should not be used.
4.3 FCelectrical,j
for corrections relating to electrical power
The parameter 𝐹𝐶𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑎𝑙,𝑗 is the mass (in grams) of
fuel of type 𝑗,
consumed for production of electrical power during the calendar year which may
be deducted from the calculation of the attained CII for the following
purposes:
.1 Electrical consumption of refrigerated
containers (on all ships where they are carried) using the calculation
methodology specified in part A of appendix 1.
.2 Electrical consumption of cargo
cooling/reliquefaction systems on gas carriers and LNG Carriers.
.3 Electrical consumption of discharge pumps
on tankers.
4.4 FCboiler,j
for corrections relating to boiler fuel consumption
The parameter FCboiler,j is the mass (in grams)
of fuel of type 𝑗,
consumed by the oil-fired boiler during the calendar year which may be deducted
from the calculation of the attained CII, for the purposes of cargo heating and
cargo discharge on tankers. The calculation methodology for 𝐹𝐶𝐵𝑜𝑖𝑙𝑒𝑟,𝑗 is specified in part B of
appendix 1.
4.5 FCothers,j
for corrections relating to other related fuel consumption devices
The parameter FCothers,j is the mass (in grams)
of fuel of type 𝑗,
consumed by standalone engine driven cargo pumps during discharge operations on
tankers which may be deducted from the calculation of the attained CII.
4.6 EEDI and EEXI
Correction factors
The EEDI correction factors as defined above in paragraph 4 may be
applied, provided they are included in the ship's EEDI Technical File or EEXI
Technical file.
APPENDIX 1
CORRECTION FACTORS FOR USE IN CII CALCULATION
Part A. FCElectrical for Corrections relating to
electrical power
1 Refrigerated
containers
For ships carrying refrigerated containers, the correction factor
FCelectrical may be applied as follows:
.1 For ships that have the ability to monitor
reefer electrical consumption, the ship may calculate reefer container kWh
consumption as follows:
FCelectrical_reefer,j = Reefer
kWh · SFOC
where:
• FCelectrical_reefer,j
(Reefer fuel oil consumption) represents the estimated fuel consumption
attributed to in-use refrigerated containers carried.
• Reefer kWh is measured on the ship by
the kWh meter counter on the ship.
• SFOC represents the specific fuel
consumption in g/kWh as a weighted average of the engines used to provide the
electrical power, as per the EEDI/EEXI Technical File or the NOx
Technical File. In the case of ships without a Technical File, a default value
of 175 g/kWh for 2 stroke engines and 200 g/kWh for 4 stroke engines may be
applied. In the case of waste heat recovery systems as defined under Category
C1 in MEPC.1/Circ.896
the SFOC to be used will be at the discretion of the Administration.
Alternatives such as
derivation of fuel consumption or kWh from auto-logged data may be used subject
to approval by the Administration. Note that ship reefer kWh consumption should
not include consumption during voyage adjustment periods.
.2 For ships that do not have the ability to
monitor reefer electrical consumption, the ship may calculate reefer kWh
consumption as follows:
FCelectrical_reefer,j = Cx
· 24 SFOCavg · (Reefer_dayssea + ∑ Reefer_daysport)
where:
• Cx represents a default
reefer consumption of 2.75 kW/h.
• Reefer_dayssea represents
the number of in-use reefer-days over the declared period and may be derived
using the number of reefer containers as recorded in the BAPLIE file multiplied
by the number of days at sea.
• SFOCavg represents the
specific fuel consumption in g/kWh as a weighted average of the engines used to
provide the electrical power, as per the EEDI/EEXI Technical File or NOx
Technical File. In the case of ships without a Technical File, a default value
of 175 g/kWh for 2 stroke engines and 200 g/kWh for 4 stroke engines may be
applied. In the case of waste heat recovery systems as defined under Category
C1 in MEPC.1/Circ.896 the SFOC to be used will be at the discretion of the
Administration.
In ports where shore-power
is not used, the number of in-use reefers at port should be calculated as:

where:
• Daysport represents number
of days in port.
• Reefer_daysport represents
the number of in-use reefer days while at port.*
• Noc Arrival represents
number of reefer containers on arrival.
• Noc Deparrture represents
number of reefer containers at departure.
In all cases, the actual number of in-use reefers carried is
documented in the BAPLIE file.
Note that ship reefer kWh consumption should not include
consumption during voyage adjustment periods.
_______________
* The number of reefers on
board while in port should be calculated to equal the number of reefers at
arrival and at departure as calculated above. Same calculation applies for
Reefer days sea in port.
2 Cargo cooling
systems on gas carriers and LNG carriers
For gas carriers and LNG carriers with electrical cargo cooling
systems or reliquefaction plants, the correction factor FCelectrical
may be applied as follows:
.1 Gas carriers and LNG carriers may
calculate cargo cooling kWh consumption as follows:
FCelectrical_cooling,j = Cooling
kWh · SFOC
where:
• FCelectrical_cooling,j (cargo
cooling fuel oil consumption) represents the estimated fuel consumption
attributed to cooling of gas cargoes.
• Cooling kWh is measured on the ship by
the kWh meter counter on the ship.
• SFOC represents the specific fuel
consumption in g/kWh associated with the relevant source of electrical power as
per the EEDI/EEXI Technical File or NOx Technical File. In the case
of ships without a Technical File, a default value of 175 g/kWh for 2 stroke
engines and 200 g/kWh for 4 stroke engines may be applied. In the case of waste
heat recovery systems as defined under Category C1 in MEPC.1/Circ.896
the SFOC to be used will be at the discretion of the Administration.
Alternatives such as derivation of fuel consumption or kWh from
auto-logged data may be used subject to approval by the Administration. Note
that cargo cooling kWh consumption should not include consumption during voyage
adjustment periods.
3 Electric cargo
discharge pumps on tankers
For tankers with directly or indirectly electrically powered discharge
pumps, the correction factor FCelectrical may be applied as follows:
.1 Tankers may calculate cargo discharge kWh
consumption as follows:
FCelectrical_dischage,j = dischage
kWh · SFOC
where:
• FCelectrical_dischage,j
(cargo discharge fuel oil consumption) represents the estimated fuel
consumption attributed to use of cargo discharge pumps.
• Dischage kWh is measured on the ship by
the kWh meter counter on the ship.
• SFOC represents the specific fuel oil
consumption in g/kWh associated with the relevant source of electrical power as
per the EEDI/EEXI Technical File or NOx Technical File. In the case
of ships without a Technical File, a default value of 175 g/kWh for 2 stroke
engines and 200 g/kWh for 4 stroke engines may be applied. In the case of waste
heat recovery systems as defined under Category C1 in MEPC.1/Circ.896 the SFOC
to be used will be at the discretion of the Administration.
Alternatives such as derivation of actual fuel consumption from
auto-logged data may be used subject to approval by the Administration. Note
that cargo cooling kWh consumption should not include consumption during voyage
adjustment periods.
Part B. FCBoiler and FCOthers for
corrections relating to cargo heating and discharge on tankers
1 FCBoiler
for cargo heating and discharge pumps on tankers
For tankers with fuel fired boilers used for cargo heating or
steam driven cargo pumps, the following correction factor may be applied for
the period that the cargo heating or discharge pumps are in operation:
.1 In the case of boilers used for cargo
heating, the amount of fuel used by the boiler (FCBoiler)
should be measured by accepted means, e.g. tank soundings, flow meters.
.2 For tankers which use steam driven cargo
pumps, the amount of fuel used by the boiler (FCBoiler)
should be measured by accepted means, e.g. tank soundings, flow meters.
Some amount of fuel consumed by the boiler during cargo heating or
discharge operations may be attributed to other purposes, e.g. calorifiers. It
is not necessary to split these out from reporting.
Note that boiler consumption should not include consumption during
voyage adjustment periods.
2 FCOthers
for discharge pumps on tankers
For tankers with discharge pumps powered by their own generator,
the amount of fuel used for the period that the discharge pumps are in
operation (𝐹𝐶𝑂𝑡ℎ𝑒𝑟𝑠)
should be measured by accepted means, e.g. tank soundings, flow meters.
Note that fuel deducted under FCOthers should not
include consumption during voyage adjustment periods.
APPENDIX 2
GUIDANCE ON REPORTING OF FUEL OIL CONSUMPTION AND DISTANCE
TRAVELLED FOR VOYAGE PERIODS WHERE THE SHIP MEETS THE CRITERIA TO APPLY ANY
VOYAGE ADJUSTMENT
In this appendix guidance is given for reporting and verification
of fuel oil consumption and distance travelled concerning voyage adjustments
when a scenario specified in regulation 3.1 of MARPOL Annex VI applies, which
may endanger safe navigation of a ship, or when sailing in ice conditions.
1 Fuel oil
consumption for voyage periods should include all the fuel oil consumed on
board including but not limited to the fuel oil consumed by the main engines,
auxiliary engines, gas turbines, boilers and inert gas generator, for each type
of fuel oil consumed, regardless of whether a