RESOLUTION MSC.98(73)
(adopted on 5 December 2000)
ADOPTION OF THE
INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS
THE MARITIME SAFETY COMMITTEE,
RECALLING Article 28(b) of the Convention on the International
Maritime Organization concerning the functions of the Committee,
NOTING the revision of chapter II-2 of the International Convention
for the Safety of Life at Sea (SOLAS), 1974 (hereinafter referred to as “the
Convention”),
RECOGNIZING the need to continue the mandatory application of the
fire safety systems required by the revised chapter II-2 of the Convention,
NOTING resolution MSC.99(73) by which it adopted, inter alia, the
revised chapter II-2 of the Convention to make the provisions of the
International Code for Fire Safety Systems (FSS Code) mandatory under the
Convention,
HAVING CONSIDERED, at its seventy-third session, the text of the
proposed FSS Code,
1. ADOPTS the
International Code for Fire Safety Systems (FSS Code), the text of which is set
out in the Annex to the present resolution;
2. INVITES
Contracting Governments to the Convention to note that the FSS Code will take
effect on 1 July 2002 upon the entry into force of the revised chapter II-2 of
the Convention;
3. REQUESTS the
Secretary-General to transmit certified copies of this resolution and the text
of the FSS Code contained in the Annex to all Contracting Governments to the
Convention;
4. FURTHER REQUESTS
the Secretary-General to transmit copies of this resolution and the Annex to
all Members of the Organization which are not Contracting Governments to the
Convention.
ANNEX
INTERNATIONAL CODE FOR FIRE
SAFETY SYSTEMS
Table of contents
Preamble
Chapter 1 General
Chapter 2 International shore connections
Chapter 3 Personnel protection
Chapter 4 Fire
extinguishers
Chapter 5 Fixed gas
fire-extinguishing systems
Chapter 6 Fixed foam fire-extinguishing systems
Chapter 7 Fixed pressure water-spraying and
water-mist fire-extinguishing systems
Chapter 8 Automatic sprinkler, fire detection and
fire alarm systems
Chapter 9 Fixed fire
detection and fire alarm systems
Chapter 10 Sample
extraction smoke detection systems
Chapter 11 Low-location lighting systems
Chapter 12 Fixed emergency fire pumps
Chapter 13 Arrangement of means of escape
Chapter 14 Fixed deck
foam systems
Chapter 15 Inert gas
systems
THE INTERNATIONAL CODE FOR
FIRE SAFETY SYSTEMS
(Fire Safety Systems Code)
PREAMBLE
1 The purpose of
this Code is to provide international standards of specific engineering
specifications for fire safety systems required by chapter II-2 of the
International Convention for the Safety of Life at Sea, 1974, as amended.
2 On or after 1 July
2002, this Code will be mandatory for fire safety systems required by the
International Convention for the Safety of Life at Sea, 1974, as amended. Any future amendment to the Code must be
adopted and brought into force in accordance with the procedure laid down in
Article VIII of the Convention.
CHAPTER 1 - GENERAL
1 Application
1.1 This code is applicable to fire safety systems as referred to in
chapter II-2 of the International Convention for the Safety of Life at Sea,
1974, as amended.
1.2 Unless expressly provided otherwise, this Code is applicable for
the fire safety systems of ships the keels of which are laid or which are at a
similar stage of construction on or after 1 July 2002.
2 Definitions
2.1 Administration means the Government
of the State whose flag the ship is entitled to fly.
2.2 Convention means the International
Convention for the Safety of Life at Sea, 1974, as amended.
2.3 Fire Safety Systems Code means the
International Code for Fire Safety Systems as defined in chapter II-2 of the
International Convention for the Safety of Life at Sea, 1974, as amended.
2.4 For the purpose of this Code, definitions provided in chapter II-2
of the Convention also apply.
3 Use of equivalents and modern
technology
In order to allow modern technology and development of fire safety
systems, the Administrations may approve fire safety systems which are not
specified in this Code if the requirements of Part F of chapter II-2 of the
Convention are fulfilled.
4 Use of toxic
extinguishing media
The use of a fire-extinguishing medium which, in the opinion of
the Administration, either by itself or under expected conditions of use gives
off toxic gases, liquids and other substances in such quantities as to endanger
persons shall not be permitted.
CHAPTER 2 - INTERNATIONAL
SHORE CONNECTIONS
1 Application
This chapter details the specifications for international shore
connections as required by chapter II-2 of the Convention.
2 Engineering
specifications
2.1 Standard dimensions
Standard dimensions of flanges for the international shore
connection shall be in accordance with the following table:
Table 2.1 - Standard dimensions for international shore
connections
|
Description |
Dimension |
|
Outside
diameter |
178
mm |
|
Inside
diameter |
64
mm |
|
Bolt
circle diameter |
132
mm |
|
Slots
in flange |
4
holes 19 mm in diameter spaced equidistantly on a bolt circle of the above
diameter, slotted to the flange periphery |
|
Flange
thickness |
14.5
mm minimum |
|
Bolts
and nuts |
4,
each of 16 mm diameter, 50 mm in length |
2.2 Materials and accessories
International shore connections shall be of steel or other
equivalent material and shall be designed for 1.0 N/mm2
services. The flange shall have a flat
face on one side and, on the other side, it shall be permanently attached to a
coupling that will fit the ship's hydrant and hose. The connection shall be kept aboard the ship
together with a gasket of any material suitable for 1.0 N/mm2
services, together with four bolts of 16 mm diameter and 50 mm in length, four
16 mm nuts, and eight washers.
CHAPTER 3 - PERSONNEL
PROTECTION
1 Application
This chapter details the specifications for personnel protection
as required by chapter II-2 of the Convention.
2 Engineering
specifications
2.1 Fire-fighter's outfit
A fire-fighter's outfit shall consist of a set of personal
equipment and a breathing apparatus.
2.1.1 Personal equipment
Personal equipment shall consist of the following:
.1 protective clothing of material to
protect the skin from the heat radiating from the fire and from burns and
scalding by steam. The outer surface shall be water-resistant;
.2 boots of rubber or other electrically
non-conducting material;
.3 rigid helmet providing effective
protection against impact;
.4 electric safety lamp (hand lantern) of
an approved type with a minimum burning period of 3 h. Electric safety lamps on tankers and those
intended to be used in hazardous areas shall be of an explosion-proof type; and
.5 axe with a handle provided with
high-voltage insulation.
2.1.2 Breathing apparatus
Breathing apparatus shall be a self-contained compressed
air-operated breathing apparatus for which the volume of air contained in the
cylinders shall be at least 1,200 l, or other self-contained breathing
apparatus which shall be capable of functioning for at least 30 min. All air cylinders for breathing apparatus
shall be interchangeable.
2.1.3 Lifeline
For each breathing apparatus a fireproof lifeline of at least 30 m
in length shall be provided. The
lifeline shall successfully pass an approval test by statical load of 3.5 kN
for 5 min without failure. The lifeline shall be capable of being attached by
means of a snap-hook to the harness of the apparatus or to a separate belt in
order to prevent the breathing apparatus becoming detached when the lifeline is
operated.
2.2 Emergency
escape breathing devices (EEBD)
2.2.1 General
2.2.1.1 An EEBD is a supplied air or oxygen device only used for escape
from a compartment that has a hazardous atmosphere and shall be of an approved
type.
2.2.1.2 EEBDs shall not be used for fighting fires, entering oxygen
deficient voids or tanks, or worn by fire-fighters. In these events, a self-contained breathing
apparatus, which is specifically suited for such applications, shall be used.
2.2.2 Definitions
2.2.2.1 Face piece means a face covering that is designed to form a
complete seal around the eyes, nose and mouth which is secured in position by a
suitable means.
2.2.2.2 Hood means a head covering which completely covers the head, neck,
and may cover portions of the shoulders.
2.2.2.3 Hazardous atmosphere means any atmosphere that is immediately
dangerous to life or health.
2.2.3 Particulars
2.2.3.1 The EEBD shall have a service duration of at
least 10 min.
2.2.3.2 The EEBD shall include a hood or full face piece, as appropriate,
to protect the eyes, nose and mouth during escape. Hoods and face pieces shall be constructed of
flame resistant materials and include a clear window for viewing.
2.2.3.3 An inactivated EEBD shall be capable of being carried hands-free.
2.2.3.4 An EEBD, when stored, shall be suitably protected from the
environment.
2.2.3.5 Brief instructions or diagrams clearly illustrating their use
shall be clearly printed on the EEBD.
The donning procedures shall be quick and easy to allow for situations
where there is little time to seek safety from a hazardous atmosphere.
2.2.4 Markings
Maintenance requirements, manufacturer’s trademark and serial
number, shelf life with accompanying manufacture date and name of approving
authority shall be printed on each EEBD.
All EEBD training units shall be clearly marked.
CHAPTER 4 - FIRE
EXTINGUISHERS
1 Application
This chapter details the specifications for fire extinguishers as
required by chapter II-2 of the Convention.
1.2 Type approval
All fire extinguishers shall be of approved types and designs
based on the guidelines developed by the Organization.*
_______________________
* Refer to the Guidelines
for marine portable fire extinguishers adopted by the Organization by
resolution A.602(15).
2 Engineering
specifications
2.1 Fire extinguisher
2.2.1 Quantity of medium
2.2.1.1 Each powder or carbon
dioxide extinguisher shall have a capacity of at least 5 kg and each foam
extinguisher shall have a capacity of at least 9 l. The mass of all portable fire extinguishers
shall not exceed 23 kg and they shall have a fire-extinguishing capability at
least equivalent to that of a 9 l fluid extinguisher.
2.2.1.2 The Administration shall
determine the equivalents of fire extinguishers.
2.2.2 Recharging
Only refills approved for the fire extinguisher in question shall
be used for recharging.
2.2 Portable foam
applicators
A portable foam applicator unit shall consist of a foamnozzle of
an inductor type capable of being connected to the fire main by a fire hose,
together with a portable tank containing at least 20 l of foam-making
liquid and one spare tank of foam making liquid. The nozzle shall be capable of producing
effective foam suitable for extinguishing an oil fire, at the rate of at least
1.5 m3/min.
CHAPTER 5 - FIXED GAS
FIRE-EXTINGUISHING SYSTEMS
1 Application
This chapter details the specifications for fixed gas
fire-extinguishing systems as required by chapter II-2 of the Convention.
2 Engineering specifications
2.1 General
2.1.1 Fire-extinguishing medium
2.1.1.1 Where the quantity of the
fire-extinguishing medium is required to protect more than one space, the
quantity of medium available need not be more than the largest quantity
required for any one space so protected.
2.1.1.2 The volume of starting air
receivers, converted to free air volume, shall be added to the gross volume of
the machinery space when calculating the necessary quantity of the
fire-extinguishing medium.
Alternatively, a discharge pipe from the safety valves may be fitted and
led directly to the open air.
2.1.1.3 Means shall be provided for
the crew to safely check the quantity of the fire-extinguishing medium in the
containers.
2.1.1.4 Containers for the storage
of fire-extinguishing medium and associated pressure components shall be
designed to pressure codes of practice to the satisfaction of the
Administration having regard to their locations and maximum ambient
temperatures expected in service.
2.1.2 Installation requirements
2.1.2.1 The piping for the
distribution of fire-extinguishing medium shall be arranged and discharge
nozzles so positioned that a uniform distribution of the medium is obtained.
2.1.2.2 Except as otherwise
permitted by the Administration, pressure containers required for the storage
of fire-extinguishing medium, other than steam, shall be located outside the
protected spaces in accordance with regulation II-2/10.4.3 of the
Convention.
2.1.2.3 Spare parts for the system
shall be stored on board and be to the satisfaction of the Administration.
2.1.3 System control requirements
2.1.3.1 The necessary pipes for
conveying fire-extinguishing medium into the protected spaces shall be provided
with control valves so marked as to indicate clearly the spaces to which the
pipes are led. Suitable provision shall be made to prevent inadvertent release
of the mediuminto the space. Where a
cargo space fitted with a gas fire-extinguishing system is used as a passenger
space, the gas connection shall be blanked during such use. The pipes may pass through accommodations
providing that they are of substantial thickness and that their tightness is
verified with a pressure test, after their installation, at a pressure head not
less than 5 N/mm2. In
addition, pipes passing through accommodation areas shall be joined only by
welding and shall not be fitted with drains or other openings within such
spaces. The pipes shall not pass through
refrigerated spaces.
2.1.3.2Means shall be provided for
automatically giving audible warning of the release of fire-extinguishing
medium into any ro-ro spaces and other spaces in which personnel normally work
or to which they have access. The pre-discharge
alarm shall be automatically activated (e.g., by opening of the release cabinet
door). The alarm shall operate for the
length of time needed to evacuate the space, but in no case less than 20 s
before the medium is released.
Conventional cargo spaces and small spaces (such as compressor rooms,
paint lockers, etc.) with only a local release need not be provided with such
an alarm.
2.1.3.3The means of control of any
fixed gas fire-extinguishing system shall be readily accessible, simple to operate
and shall be grouped together in as few locations as possible at positions not
likely to be cut off by a fire in a protected space. At each location there shall be clear
instructions relating to the operation of the system having regard to the
safety of personnel.
2.1.3.4 Automatic release of
fire-extinguishing medium shall not be permitted, except as permitted by the
Administration.
2.2 Carbon dioxide systems
2.2.1 Quantity of fire extinguishing medium
2.2.1.1 For cargo spaces the
quantity of carbon dioxide available shall, unless otherwise provided, be
sufficient to give a minimum volume of free gas equal to 30% of the gross
volume of the largest cargo space to be protected in the ship.
2.2.1.2 For machinery spaces the
quantity of carbon dioxide carried shall be sufficient to give a minimum volume
of free gas equal to the larger of the following volumes, either:
.1 40% of the gross volume of the largest
machinery space so protected, the volume to exclude that part of the casing
above the level at which the horizontal area of the casing is 40% or less of
the horizontal area of the space concerned taken midway between the tank top
and the lowest part of the casing; or
.2 35% of the gross volume of the largest
machinery space protected, including the casing.
2.2.1.3 The percentages specified in
paragraph 2.2.1.2 above may be reduced to 35% and 30%, respectively, for cargo
ships of less than 2,000 gross tonnage where two or more machinery spaces,
which are not entirely separate, are considered as forming one space.
2.2.1.4 For the purpose of this paragraph the volume of free carbon
dioxide shall be calculated at 0.56 m3/kg.
2.2.1.5For machinery spaces the
fixed piping system shall be such that 85% of the gas can be discharged into the
space within 2 min.
2.2.2 Controls
Carbon dioxide systems shall comply with the following
requirements:
.1 two separate controls shall be provided
for releasing carbon dioxide into a protected space and to ensure the
activation of the alarm. One control
shall be used for opening the valve of the piping which conveys the gas into
the protected space and a second control shall be used to discharge the gas
from its storage containers; and
.2 the two controls shall be located inside
a release box clearly identified for the particular space. If the box containing the controls is to be
locked, a key to the box shall be in a break-glass-type enclosure conspicuously
located adjacent to the box.
2.3 Requirements of steam systems
The boiler or boilers available for supplying steam shall have an
evaporation of at least 1 kg of steam per hour for each 0.75 m3 of
the gross volume of the largest space so protected. In addition to complying with the foregoing
requirements the systems in all respects shall be as determined by, and to the
satisfaction of, the Administration.
2.4 Systems using gaseous products of fuel
combustion
2.4.1 General
Where gas other than carbon dioxide or steam, as permitted by
paragraph 2.3, is produced on the ship and is used as a fire-extinguishing
medium, the system shall comply with the requirements in paragraph 2.4.2.
2.4.2 Requirements of the systems
2.4.2.1 Gaseous products
Gas shall be a gaseous product of fuel combustion in which the
oxygen content, the carbon monoxide content, the corrosive elements and any
solid combustible elements in a gaseous product shall have been reduced to a
permissible minimum.
2.4.2.2 Capacity of fire-extinguishing systems
2.4.2.2.1 Where such gas is used
as the fire-extinguishing medium in a fixed fire-extinguishing system for the
protection of machinery spaces, it shall afford protection equivalent to that
provided by a fixed system using carbon dioxide as the medium.
2.4.2.2.2 Where such gas is used
as the fire-extinguishing medium in a fixed fire-extinguishing system for the
protection of cargo spaces, a sufficient quantity of such gas shall be
available to supply hourly a volume of free gas at least equal to 25 % of the
gross volume of the largest space protected in this way for a period of 72
h.
2.5 Equivalent fixed gas fire-extinguishing
systems for machinery spaces and cargo pump rooms
Fixed gas fire-extinguishing systems equivalent to those specified
in paragraphs 2.2 to 2.4 shall be approved by the Administration based on the
guidelines developed by the Organization.*
_________________________
* Refer to the Revised
guidelines for the approval of equivalent fixed gas fire-extinguishing systems,
as referred to in SOLAS 74, for machinery spaces and cargo pump rooms (MSC/Circ.848).
CHAPTER 6 - FIXED FOAM
FIRE-EXTINGUISHING SYSTEMS
1 Application
This chapter details the specifications for fixed foam
fire-extinguishing systems as required by chapter II-2 of the Convention.
2 Engineering
specifications
2.1 General
Fixed foam fire-extinguishing systems shall be capable of
generating foam suitable for extinguishing oil fires.
2.2 Fixed high-expansion foam
fire-extinguishing systems
2.2.1 Quantity and performance of foam concentrates
2.2.1.1The foam concentrates of
high-expansion foam fire-extinguishing systems shall be approved by the
Administration based on the guideline developed by the Organization.**
_________________________
** Refer to the Guidelines for performance and
testing criteria and surveys of high expansion foam concentrates for
fire-extinguishing systems (MSC/Circ.670).
2.2.1.2Any required fixed
high-expansion foam system in machinery spaces shall be capable of rapidly discharging
through fixed discharge outlets a quantity of foam sufficient to fill the
greatest space to be protected at a rate of at least 1 m in depth per
minute. The quantity of foam-forming
liquid available shall be sufficient to produce a volume of foam equal to five
times the volume of the largest space to be protected. The expansion ratio of
the foam shall not exceed 1,000 to 1.
2.2.1.3 The Administration may
permit alternative arrangements and discharge rates provided that it is
satisfied that equivalent protection is achieved.
2.2.2 Installation requirements
2.2.2.1 Supply ducts for delivering foam, air intakes
to the foam generator and the number of foam-producing units shall in the
opinion of the Administration be such as will provide effective foam production
and distribution.